Power Generators
spacer
arrow Mitsubishi MGS Series
spacer
arrow MTU GAS System Series
spacer
arrow Perkins Generators
spacer
arrow Spare Parts
spacer
HVAC Systems
spacer
arrow Turnkey HVAC Solutions
spacer
arrow Spare Parts
spacer
Rubber Foam Insulation
spacer
arrow ForteFlex
spacer
Products
spacer
 

Perkins Diesel Generator Set

From 9kva to 500 kva

400 V / 1500 rpm

Prime Rated: ISO 8528:
Prime Power is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals.

The permissible average power output during a 24 hours period shall not exceed 80% of the prime power. 10% overload is allowed.
Standby Power (ISO 3046 Fuel Stop Power):
Power available for use at variable loads for limited annual time (500 h), within the followinglimits of maximum operating time: 100% loads
25h per year, 90% loads 200h per year.
No overload is available.

Generating set specifications:

Engine and alternator are directly coupled and mounted on heavy duty steel frame.The genset includes the following:
• Steel base frame with anti-vibration mountings.
• Attached tropical radiator with engine driven fan and protecting guards.
• (12/24) V DC starter motors and charge alternator.
• (12/24) V DC starting battery "Lead Acid" mounted onto a rack and cabled.
• Lube oil drain taps with extended flexible drain pipe.
• Spin on type fuel oil filters.
• Flexible fuel lines.
• Electronic governor.
• Spin on type lube oil filters. A Standard dry type air filter. A Engine protection.
• Low lube oil pressure. A High water temperature.
• Fuel stop solenoid (12/24V). A Supplied separate fuel tank (optional).
• Rating is at 380/415V, 50Hz, 0.8 p.f, 50'c ambient and 100% RH.

Control Panel Specifications:
Deep Sea module control panel mounted at the alternator end of the generating set in a vibration isolated sheet enclosure. It consists of the following:

• One voltmeter with phase selector switches (7 positions).
• One AC ammeter with selector switches (4 positions).
• One combined frequency / techometer.
• One hours run meter.
• One lube oil pressure gauge.
• One water temperature gauge.
• One battery condition voltmeter.
• One protection circuitry board.
• One ignition key.
• Indicating Led's with immediate shutdown for:A Low oil pressure A High coolant temperature A Over / under speed

Perkins Generator Set


Model Engine Power (kva) Cyl
    Prime Std By  
FT-9 403C-11G 9.1
10
3
FT-13 403C-11G 11
13
3
FT-15 403C-15G 1 5
16.5
3
FT-20 404C-22G 20.3
22.7
4
FT-30 1103A-33G 30
33
3
FT-45 1103A-33TG1 45
50
3
FT-60 1103A-33TG2 60
66
3
FT-80 1104A-44TG2 80
88
4
FT-90 1006TG1 93
103
6
FT-100 1104C-44TA02 100
110
4
FT-135 1006-TAG 136
150
6
FT-150 1006TAG2 150
165
6
FT-200 1306C-E87TAG3 208
229
6
FT-220 1306C-E87TAG4 228
250
6
FT-235 13060-E37TAG5 235
258
6
FT-250 1306C- E87TAG6 250
275
6
FT-300 2306CE-14TAG2 300
330
6
FT-350 2306A-E14TAG2 350
400
6
FT-400 2306A-E14TAG3 400
450
6
FT-450 2506A-E15TAG1 455
500
6
FT-500 2506A-E15TAG2 500
550
6







 




© Copyright 2007. Forte Pakistan All rights reserved